Siemens SIMATIC TIM 3V-IE DNP3 System Manual page 151

Industrial remote communication telecontrol
Table of Contents

Advertisement

and is unique throughout the project. The subscriber number of a CPU that is assigned to
a TIM module is used as the address for DNP3 communication.
Changing the subscriber number
To change the subscriber number, click on the required subscriber. By clicking again on
the subscriber number, the "Subscriber no." box can be edited (alternatively also using
the function key 2 or the Edit / Change Subscriber menu). You can assign a subscriber
number that has not yet been assigned from the range 1 ... 65519.
The subscriber number 0 is reserved and cannot be assigned.
● Red. Subscriber no.
The redundant subscriber number is used only when there is a redundant partner for the
subscriber in question. The number specifies the common subscriber number under
which the redundant system can be addressed by other subscribers.
In the case of an S7-400H CPU, the common subscriber number is displayed in the "Red.
Subscriber no." column. At the same time, this is the subscriber number of the primary
redundancy partner.
You can change the subscriber numbers of the two partners in the appropriate input field
for the numbers or in the "Properties - CPU redundant" dialog. You can open this dialog
by expanding the "Redundant H CPUs" directory in the directory tree, selecting the H
CPU below it and then selecting "Properties" in the shortcut menu (right mouse button). In
this dialog, you can also change the primary CPU.
● Subscriber no. of red. Partner
The "Subscriber number of the redundant partner" only has an entry when there is a
redundant partner for this subscriber. The parameter specifies which of the subscribers
belong to a redundant relationship.
● Subscriber type
The "Subscriber type" specifies the class of subscriber involved. This cannot be changed
by the user.
● Module
The module, application or PC/PG name. This can be changed in the configuration. As
default, this is the name of the module type or the application as specified in the
configuration.
● Station
Name of the station assigned in the network configuration in "NetPro".
● SINAUT connected
Specifies whether or not a telecontrol connection was configured for the subscriber.
● SINAUT library
Name of the TD7 block library for CPUs (not for DNP3) or for TD7onTIM-compliant TIM
modules.
You set the parameters for some subscriber-related properties in the "Properties of
subscriber" dialog, see section The "Properties of Subscriber" dialog (Page 152).
TIM DNP3
System Manual, 12/2015, C79000-G8976-C253-04
The SINAUT Configuration Tool
6.5 The Subscriber Administration
151

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simatic tim 4r-ie dnp3Tim 3v-ie dnp3Tim 4r-ie dnp3