Cessna 182S Skylane Information Manual page 57

Hide thumbs Also See for 182S Skylane:
Table of Contents

Advertisement

SECTION
3
EMERGENCY PROCEDURES
CESSNA
MODEL
182S
lf
fire has been
extinguished and electrical power
is
necessary
for continuance
of
flight
to
nearest suitable airpoft or landing area:
7.
Master Switch --
ON.
8.
Circuit Breakers -- CHECK for faulty circuit, do not reset.
.
9.
Radio Switches --
OFF.
I
10.
Avionics Master Switch --
ON.
-
11. Radio/Electrical Switches
-
ON one at a time, with delay
after
each
until
shott
circuit is localized.
CABIN
FIRE
1. Master Switch
-
OFF.
2. Vents/Cabin Air/Heat
-
CLOSED
(to
avoid drafts).
3.
Fire Extinguisher
-
AGTIVATE
(if
available).
¡[,mmtruc
AFTER
DISCHARGING
FIRE
EXTINGUISHER
AND
ASCERTAINING
THAT F¡RE HAS
BEEN
EXTINGUISHED,
VENTILATE
THE CABIN.
4.
Vents/Cabin
Air/Heat -- Open
when
it
is ascertained
that fire
is
completely extinguished.
5.
Land the airplane as soon
as
possible
to
inspecl for damage.
WING
FIRE
1. Landing/Taxi Light Switches
-
OFF.
2. Navigation Light
Switch
-
OFF.
3.
Strobe Light Switch
-
OFF.
4. Pitot
Heat
Switch
-
OFF.
NOTE
Perform
a
sideslip
to
keep
the
flames away from
the
fuel
tank and cabin. Land as soon as possible using flaps
only
as required for
final
approach
and
touchdown.
3-8