Huawei RH2288 V3 User Manual page 221

Table of Contents

Advertisement

RH2288 V3 Server
User Guide
The exported configuration data can be used to quickly restore the server configuration after
the mainboard is replaced. For details, see Import/Export in
User
Step 4 Wear an ESD wrist strap. For details, see
Step 5 Determine the cabinet number and chassis number of the server, and label its panel to prevent
misoperations.
Step 6 Power off the RH2288 V3. For details, see
Step 7 Remove all external cables such as power and network cables.
Step 8 Remove the RH2288 V3 and put it on an ESD desktop. For details, see
Server.
Step 9 Remove the chassis cover. For details, see
Step 10 Remove the supercapacitor if it is installed. For details, see
Supercapacitor (Screw-in RAID Controller
Step 11 Remove the riser cards. For details, see
Step 12 Remove the air duct. For details, see
Step 13 Remove all fan modules. For details, see
Step 14 Press and hold down the latches on both sides of a fan module bracket, and lift the bracket.
Use the same method to lift the other fan module bracket. See steps (1) and (2) in
7-90.
Issue 32 (2019-03-28)
Guide.
NOTE
l iBMC 2.32 and later versions support the import and export of configuration files.
l After mainboard replacement, you can directly import the iBMC and BIOS configuration data
exported from the iBMC. However, the exported configuration files do not contain password
information. You need to manually configure the password for the iBMC user. For details, see
Import/Export in
Huawei Rack Server iBMC User
l If the iBMC is inaccessible or the iBMC and BIOS configuration data is not exported before the
mainboard is replaced, you need to manually configure the iBMC and BIOS after replacing the
mainboard.
l The iBMC and BIOS configuration files exported from the iBMC contain configuration items. For
details, see "Configuration File Description" in the
Copyright © Huawei Technologies Co., Ltd.
Guide.
Huawei Rack Server iBMC User
1 Safety
Instructions.
4.2 Powering Off the
7.11 Removing the Chassis
7.33 Removing the
Card).
7.19 Removing the Riser
7.13 Removing the Air
7.15 Removing a Fan
7 Replacing Parts
Huawei Rack Server iBMC
Guide.
Server.
3.6 Removing the
Cover.
Card.
Duct.
Module.
Figure
209