Huawei RH2288 V3 User Manual page 118

Table of Contents

Advertisement

RH2288 V3 Server
User Guide
l
Issue 32 (2019-03-28)
Figure 5-4 Querying the health status for the RH2288 V3
d.
Clear alarms. For details, see the
NOTE
If the query result in
Check the RH2288 V3 using the iBMC CLI.
a.
Log in to the iBMC CLI.
i.
Set an IP address for the PC, and ensure that the IP address is on the same
network segment as the iBMC management network port.
ii.
Connect the PC to the RH2288 V3 iBMC management network port by using
a network cable.
iii. Run the Secure Shell (SSH) tool on the PC, and enter the IP address of the
iBMC management network port, user name, and password to log in.
NOTE
By default, SSH is used to log in to iBMC. If the SSH service is disabled, enable it by
choosing Config > Service Settings on the iBMC WebUI.
b.
View the RH2288 V3 version information.
Check that the RH2288 V3 versions meet site requirements.
Hi1710 / # ipmcget -d v
------------------- iBMC INFO -------------------
IPMC
IPMI
CPLD
Active iBMC
Active iBMC
Backup iBMC
SDK
SDK
Active Uboot
Backup Uboot
----------------- Product INFO -----------------
Product
Product
Product
BIOS
-------------- Mother Board INFO ---------------
Mainboard
Mainboard
------------------- lexible NIC INFO -------------------
SM211
SM211
Copyright © Huawei Technologies Co., Ltd.
Huawei Rack Server Alarm Handling
c
indicates that no alarm is generated for the server, skip this step.
CPU:
Hi1710
Version:
2.0
Version:
(U46)1.05
Version:
(U25)1.26
Built:
08:26:05 Dec 23 2014
Version:
1.26
Version:
1.47
Built:
08:28:02 Dec 19 2014
Version:
1.1.29 (Oct 13 2014 - 15:23:00)
Version:
1.1.29 (Oct 13 2014 - 15:23:00)
ID:
0x0001
Name:
RH2288
Version:
V3
Version:
(U47)1.19
BoardID:
0x000f
PCB:
.B
BoardID:
0x0017
PCB:
.A
5 Configuring the RH2288 V3
(iBMC).