154771-1CD
2 Features
The MOTOMAN-EPX1750 & EPX2050 is designed for easy-handling and to consider safety
first in operation.
2.1
Methods of Protection
The MOTOMAN-EPX1750 & EPX2050 is evaluated as Type X Purged for use in Class Ι,
Division 1, Groups A, B, C and D indoor hazardous (classified) Iocations T4, and appear in the
Factory Mutual (FM) Research Approval Guide.They have the construction of protection as
follows:
Method of Protection;
• The pressurized explosion-proof method prevents explosive gas from entering the
manipulator by supplying a protective gas, such as clean air or an inert gas, to keep the
internal air pressure constant.
• The Intrinsic-safety explosion-proof method prevents explosive gas from igniting by
electric spark and heat.
Install the MOTOMAN-EPX1750 & EPX2050 in a location that meets the requirements of
Area Classification "Division1" prescribed in FM Approval Standard.
DANGER
2-1
2 Features
2.1 Methods of Protection
HW0485080
16 of 66