Type
Customers desiring to perform further environmental testing of the CP3005-SA must
contact Kontron for assistance prior to performing any such testing.
Boards without conformal coating must not be exposed to a change of temperature which
can lead to condensation, as it may cause irreversible damage especially when the board is
powered up again.
Kontron does not accept any responsibility for damage to products resulting from
destructive environmental testing.
www.kontron.com
Aspect
Standard
Bump Shock
IEC60068-2-29
CP3005-SA – Rev. 0.6 Preliminary
Remarks
30 (g) acceleration
9 (ms) shock duration half sine
3 number of shocks per
direction (total: 18)
6 directions
5 (s) recovery time
Test parameters:
15 (g) acceleration
11 (ms) shock duration half
sine
500 number of shocks per
direction
6 directions
5 (s) recovery time