Problem
Symptom: Starter cranks slowly or will not operate.
Low battery output
Loose or corroded battery connections Clean and tighten loose connections.
Controls not in NEUTRAL
Controls not in NEUTRAL
Controls not in NEUTRAL
Relay not functioning
Main fuse defective/blown
Key power fuse blown
Key switch worn or terminals loose
Switch at Interlock not closed or
defective
Crankcase oil too high viscosity
214733
TROUBLESHOOTING
Solution
Check battery charge.
Move GSL to NEUTRAL.
Move steering wheel to CENTER
position.
Disengage header.
Check relay and wire connections.
Replace main fuse.
Replace.
Contact Dealer.
Adjust switch or replace Contact your
Dealer.
Use recommended oil.
406
Section
Maintaining a Battery, page 342
Maintaining a Battery, page 342
Starting the Engine, page 115
Driving in Reverse in Cab-Forward
Mode, page 127
Engaging and Disengaging the Header,
page 190
Checking and Replacing Fuses, page
379
Checking and Replacing Fuses, page
379
Checking and Replacing Fuses, page
379
Contact Dealer
Contact Dealer
5.1.3 Lubricants, Fluids, and System
Capacities, page 249