a.
Table 2-4
Pulsed output with 50 s t t
b. Maximum base current is 500 mA for the pulse with 50 s t 1 ms, and 50 mA for
the pulse with 50 s t 2.5 ms or 50 s t 10 ms.
c. Maximum duty cycle is 99.9999 % for the pulse with 50 s t t
the pulse with 50 s t 1 ms, 50 s t 2.5 ms, or 50 s t 10 ms.
Table 2-3
Range
value
resolution
0.2 V
2 V
20 V
200 V
a.
Table 2-4
output with 50 s t t
b. Maximum duty cycle is 99.9999 % for the pulse with 50 s t t
the pulse with 50 s t 1 ms, 50 s t 2.5 ms, or 50 s t 10 ms.
shows the limitations when using Channels 1 and 2 for DC output or
Voltage Output Range
DC output voltage
Setting
or pulse peak/base
voltage
0.1 V
0 |V| 0.21 V
1 V
0 |V| 2.1 V
10 V
0 |V| 6 V
6 V < |V| 21 V
100 V
0 |V| 6 V
6 V < |V| 21 V
21 V < |V| 210 V
0 |V| 180 V
0 |V| 200 V
shows the limitations when using Channels 1 and 2 for DC output or Pulsed
(=99.9999 ks).
max
Keysight B2961A/B2962A User's Guide, Edition 3
(=99.9999 ks).
max
Maximum current
DC
output
3.03 A
1.515 A
3.03 A
1.515 A
105 mA
Introduction
Power Source
, and 2.5 % for
max
a
Pulse width t
Pulsed
output
3.03 A with 50 s t t
10.5 A with 50 s t 1 ms
1.515 A with 50 s t t
3.03 A with 50 s t t
10.5 A with 50 s t 1 ms
1.515 A
50 s t t
105 mA
1.05 A
50 s t 10 ms
1.515 A
50 s t 2.5 ms
, and 2.5 % for
max
b
max
max
max
max
2-13