Installation
3.5.5 Drain connection
There must be a waste pipe with an effective trap for the machine's waste water
and for water used for cleaning. The floor drain capacity can be found in the
TECHNICAL SPECIFICATIONS.
Machines without a drain pump
The waste water system connected to (3) should consist of a 50 mm metal pipe
that will withstand mechanical impacts. The drain must run to a floor drain, where
its opening must be above the water level.
Ensure that the drain connection is kept in place by using e.g. cable ties in the
designated areas.
Machines with a drain pump (option)
3
avlopp_dp
Drain hose (A) consists of a spiral hose and is connected to the machine at (3)
and to the floor drain (B) as per one of the alternatives in the illustration.
Ensure that the drain connection is kept in place by using e.g. cable ties in the
designated areas.
WD-12
A
3
17
Rev. 2.0 (201706)
B
min. 25mm