Installation

3.5.6 Water connection, regardless of any option

The water pipe is connected at (2) or from below at (7) (option). If the machine is
connected to a hose, the internal diameter of the hose must be at least 12 mm.
The required water flow and pressure can be found in the TECHNICAL
There must be a stopcock on the incoming water pipe.

3.5.7 Drain connection, machines without a drain pump

The waste water system connected to (3) should consist of a 50 mm metal pipe
that will withstand mechanical impacts. The drain must run to a floor drain, where
its opening must be above the water level. The capacity of the floor drain must be
3 litres/second.
Ensure that the drain connection is kept in place by using e.g. cable ties in the
designated areas.

3.5.8 Drain connection, machines with a drain pump

The pipe from the drain pump (which should preferably be a copper pipe with a
diameter of 22 mm) must run to a sink and the opening must be a minimum of 25
mm above the sink.
Ensure that the drain connection is kept in place by using e.g. cable ties in the
designated areas.

3.5.9 Bleeding the hood lifting cylinder (option)

1.
2.
3.
4.
5.
WD-6
Close the hood.
Loosen the hose connection of the first air cylinder approx. 2-3 turns using
a 13 mm box wrench.
Keep the hood in the closed position. Press the up button. Check that only
water and no air comes out of the hose connection. Otherwise repeat the
procedure.
Tighten the hose connection with the hose still in the lower position.
Repeat the same procedure with the second cylinder.