Installation instructions
3.5.5 Water connection, regardless of any options
3.5.6 Drain/waste pipe connection
•
A stopcock must be installed on the incoming lines, which are fitted with a
filter.
•
It is important that the water supply has sufficient pressure to ensure the
correct flow of water to the machine. The required water flow and pressure
can be found in the TECHNICAL SPECIFICATIONS.
•
The machine is equipped with a "Break tank".
Hot water (2) and cold water (1) are connected to a standard machine. If the ma-
chine is equipped with ECO flow (option), which only has cold water, it is connect-
ed to (2). If the machine is connected with a hose, this should be steel braided
and have an internal diameter of at least 12 mm.
The waste water system connected to (4) should consist of a 50 mm metal pipe
that will withstand mechanical impacts. The waste pipe must run to a floor drain,
where its opening must be above the water level.
WD-90 DUO
21
Rev. 2.0 (202204)