Installation
3.4.3 Electrical connection
This symbol on a machine part warns of electrical equipment. The part may only
be removed by a qualified electrician. The machine is sensitive to electrostatic
discharge (ESD), which is why a static electricity bracelet must be used when
handling the electronics.
Information on electrical connection is shown on the machine's wiring diagram.
This is located on the inside of the front plate.
The machine should be connected to a lockable main switch. This should be
placed on the wall well protected against water and steam emissions when open-
ing the door.
The machine is supplied with the electrical cable (3) connected.
3.4.4 Water connection
The water pipe is connected at (1). If the machine is connected with a hose, the
internal diameter of the hose must be at least 12 mm.
The required water flow and pressure can be found in the TECHNICAL SPECI-
FIKATIONS.
A shut-off cock must be installed on the incoming pipe.
3.4.5 Drain connection. Machine without emptying pump
The drain connection (2) consists of a spiral hose. The drain is run to a floor drain,
where it must end above the water level.
Ensure that the drain connection is kept in place by using e.g. cable ties in the
designated areas.
WD-4C
10
Rev. 3.0 (201308)