Wexiodisk WD-12 Installation And User Manual page 26

Combi dishwasher
Table of Contents

Advertisement

Installation
Relay 11/J73. Relay 11. 24V AC version
(230V/400V 3-phase machine) (standard design)
Connect the equipment to be controlled between contact J73-NO and con-
nector 0V in the electrical cabinet.
Relay 11/J73. Dead closing function
(230V/400V 3-phase machine)
To use the closing function without a power supply, follow these instructions:
Remove the red connector from J73-C to J74-C.
Contact the equipment to be controlled to contacts J73-C and J73-NO.
Relay 11/J73. 230V AC version (400V 3-phase machine)
To connect a 230V AC power supply to the contact, follow these instructions:
Remove the red connector from J73-C to J74-C.
If a 230V AC version of J71 is fitted:
Connect J71-105 to J73-C using a black 0.75mm² wire.
If J71 is not fitted or is not a 230V AC version:
Connect a black 0.75mm² wire from connector X10 to contact J73-C.
Connect the equipment to be controlled between contact J73-NO and con-
nector N in the electrical cabinet.
Relay 11/J73. 230V AC version (230V 3-phase machine)
To connect a 230V AC power supply to the contact, follow these instructions:
Remove the red connector from J73-C to J74-C.
If a 230V AC version of J71 is fitted:
Connect J71-105 to J73-C using a black 0.75mm² wire.
If J71 is not fitted or is not a 230V AC version:
Connect a black 0.75mm² wire from mini-switch FU/M-2 to contact J73-C.
Connect the equipment to be controlled between contact J73-NO and con-
nector X10 in the electrical cabinet.
WD-12
22
Rev. 2.0 (201706)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents