Technical specifications
The manufacturer reserves the right to make changes to the technical data.
TECHNICAL DATA
Washing pump (kW)
Booster heater (kW)
Booster heater (machine with cold water connection) (kW) *
Booster heater (machine with condensing unit) *
Tank heater (kW)
Booster pump (kW)
Drain pump (kW) *
Heat recovery fan (kW) *
Heat recovery, cooling surface (m²) *
Tank volume (l)
Weight, machine in operation (kg)
Enclosure class (IP)
* Option
CAPACITY AND OPERATING DATA
Total washing time P1 (min.) *
Total washing time P2 (min.) *
Total washing time P3 (min.) *
Max. capacity, baskets/hour (no.)
Water consumption rinsing/programme (l) **
Sound pressure level, LPA (dBA) Normal load / Heavily soiled loads ***
Sound power level LWA (dBA) Normal load / Heavily soiled loads ***
* Factory setting. The washing time can be adjusted.
** Applies under ideal conditions. The water consumption depends on local con-
ditions. Fine adjustments can be made during installation.
*** in accordance with EN 60 335-2-58, §ZAA.2.8 with instruments that satisfy
class 1.
Measurements of the sound pressure level on site are performed in three places
20 cm from the edges of the front at a height of 1.55 m using a microphone.
When measuring sound power level, create an imaginary measurement area con-
sisting of five sides at a distance of 1 m from all edges of the machine.
WD-12
5. Technical specifications
48
Rev. 2.0 (201706)
2x2,35
12
12 + 9
15
9
0,67
0,17
0,12
11
120
480
55
1,2
3,2
5,2
100
6 - 8
66 / 65