Instructions for use
1.
2.
3.
4.
5.
6.
7.
8.
9.
All the values are laid out in tables, with each table containing a certain number
of rows, one for each value. The table containing the values for the washing tem-
perature and washing times for the various programmes is called "0.0".
The values for washing temperature and washing times are on rows 01 to 04 (in-
clusive) of table "0.0".
To select service mode and change the washing temperature and washing time,
follow these instructions:
Symbol for washing function.
Display for the table numbers and the row numbers of each table.
Symbol for final rinse.
Display of values and other information for all the row numbers in the ta-
bles.
Button for opening/closing the hood.
Use the P1 button to move between the table rows or to reset the values to
those last saved.
Use the P2 button to increase a value or move forwards between the ta-
bles.
Use the P3 button to reduce a value or move backwards between the ta-
bles.
Use the 0/1 button to enter or exit service mode.
Table 0.0
Row number
Relates to
01
Washing temperature
02
Washing time programme P1
03
Washing time programme P2
04
Washing time programme P3
When moving to service mode, the washing programme must be finished.
Press the 0/1 button (9). Both the displays (2, 4) will now show two horizon-
tal dashes "--" and the machine will be in shut-off mode.
Hold the 0/1 button (9) down for approx. 3 seconds until the top display (2)
shows "0.0". The two zeros "0.0" indicate that the machine is in service
mode.
Press P1 (6). The top display (2) will now show 01, the first row number in
the table. The bottom display (4) shows the set washing temperature flash-
ing; only values that flash when they appear can be changed. If the tem-
perature is to be changed, press P2 (7) to increase the value or P3 (8) to
reduce the value.
If the washing time for a programme is to be changed, use P1 (6) to move
to the next row number in the table. For explanations of row numbers 01,
02, 03 and 04, see table "0.0" above.
When the settings are complete, exit service mode by holding down the 0/
1 button (9) for approx. 3 seconds until the displays show two horizontal
dashes "--". The changed values are now saved.
Return to normal operating mode by then quickly pressing the 0/1 button
(9).
WD-12
33
Rev. 2.0 (201706)
Range of settings
55 - 70° C
1.0 - 6.0 min
1.0 - 6.0 min
1.0 - 6.0 min

Hide quick links: