Electricity Connection; Water Connection; Drain Connection - Wexiodisk WD-6C Installation And Operation Manual

Hide thumbs Also See for WD-6C:
Table of Contents

Advertisement

Installation

3.4.6 Electricity connection

This symbol on a component is a warning of electrical equipment. The component
may only be removed by a qualified electrician. The machine is sensitive to elec-
trostatic discharge (ESD), which is why a static electricity wristband must be used
when handling the electronics.
Information about electrical connections can be found on the machine's wiring di-
agrams. These are located on the inside of the front panel. Store the diagrams in
the electrical cabinet after installation.
The machine must be connected to a lockable mains switch. This should be
placed on a wall, well-protected from water and from the steam which escapes
when the hood is opened.
The machine is supplied with the electrical cable connected (1).

3.4.7 Water connection

The water pipe is connected to (2) or from below at (6) (option). If the machine is
connected to a hose, the internal diameter of the hose must be at least 12 mm.
The required water flow and pressure can be found in the TECHNICAL SPECIFI-
CATIONS.
There must be a stopcock on the incoming water pipe.

3.4.8 Drain connection

The waste water system connected to (3) should consist of a 50 mm metal pipe
that will withstand mechanical impacts. The drain must run to a floor drain, where
its opening must be above the water level. The capacity of the floor drain must be
3 litres/second.
Ensure that the drain connection is kept in place by using e.g. cable ties in the
designated areas.