Installation
3.5.6 Steam connection (option)
The steam connection (5) is fitted with a shut-off valve and filter. When connecting
a pipe from the ceiling, it is taken into the same area as the water pipes behind
the cover plate next to the electrical cabinet. The required steam pressure can be
found in the TECHNICAL SPECIFICATIONS.
3.5.7 Condensation connection (option)
A condensation connection (4) is only provided on steam-heated machines. The
pipe is connected to the system's steam boiler.
3.5.8 Drain connection
The waste water system must have 50 mm metal pipes that will withstand collision
or 50 mm plastic pipes. The waste water pipe must be connected to a floor drain
and the opening of the pipe must be above the water level. The floor drain capac-
ity can be found in TECHNICAL SPECIFICATIONS.
3.5.9 Ventilation
The machine has a ventilation connection (7) which allows an external ventilation
duct to be connected.The connection to the ventilation system is made using a
strain-relief grip.
WD-18CW
16
Rev. 3,0 (201802)