Installation

3.5.6 Bleeding the booster pump

When starting up the machine, bleed the booster pump using the screw on the
top of the pump housing.

3.5.7 Bleeding the hood lifting cylinder

1.
2.
3.
4.
WD-12
Close the hood.
Loosen the hose connection of the first air cylinder approx. 2-3 turns using
a 13 mm box wrench.
Keep the hood in the closed position. Press the up button. Check that only
water and no air comes out of the hose connection. Otherwise repeat the
procedure.
Tighten the hose connection with the hood still in the lower position.