Operators can select from the following trap events to receive up to three SNMP traps and three
email notifications when they occur:
Event
Message (email
notification)
Lamp end of life
Lamp has reached
end of life
Lamp end of life
Lamp end of life
cleared
cleared
Lamp fault
Lamp fault has
occurred
Lamp fault cleared
Lamp fault has been
cleared
Fan stall
Fan stalled
Fan no longer stalled
Fan stall cleared
Thermal sensor
Thermal sensor
warning
warning
Thermal sensor error
Thermal sensor error
Thermal sensor OK
Thermal sensor OK
Projector powered on
Projector turned on
(Standby to Lamps
(lamps on)
On)
Projector powered
Projector turned off
off (Lamps On to
(lamps off)
Standby)
No video input signal
No video input signal
Video input signal
Video input signal
detected
detected
Lamp door open
Lamp door has been
opened
Lamp door closed
Lamp door has been
closed
Email notification
When a trap occurs while Email Notification is selected for the event, an individual email is sent to
each user defined email recipient. The SNMP menu allows up to three email address (up to 64
characters in length) to request notifications from the system during a trap event.
The resulting email is in the following format:
From: <from@email.com>
To: <to@email.com>
Subject: Christie Mirage M Series Projector SNMP Notification
Mirage M Series User Manual
020-101942-02 Rev. 1 (10-2018)
http://www.pureglare.com.au
Parameters
Trap config.
menu text
Lamp Number
Lamp Life
Lamp Hours Elapsed
Lamp Number
Lamp Number
Lamp Fault
Lamp Fault
Description
Lamp Number
Fan Name
Fan Stall
Thermal Sensor
Thermal Sensors
Name
Thermal Sensor Text
None
Power
Frequency
Signal Lost/Detected
Lamp Number
Lamp Door
Monitoring and Maintenance
Default
notification
setting
SNMP Trap + Email
Disabled
109