Cabling a Multi-Chassis Configuration
Multi-Chassis 2+2 Configuration
The figure shows the 2+2 connections for two fabric planes. To complete the configuration, you must repeat
the cabling for the remaining four fabric planes until all 12 S2 cards are connected.
Figure 82: Cisco NCS 6000 Multi-Chassis 2+2 Configuration with 12 S2 FC ' s
The following table shows the cabling plan for a 2+2 multi-chassis configuration with 12 SC FCs installed.
FCC0 has a fabric instance 0 for planes 0 though 5 in FCC0 (6 SC FCs in slots 0 through 5), and fabric instance
1 in FCC1 (also in slots 0 through 5). Other mappings are possible (for example, you can put both instances
of planes 0 through 2 in FCC0, and planes 3 though 5 in FCC1 but the following table and software
configuration assume that instance 0 is in FCC0 and instance 1 is in FCC1.
Cisco Network Convergence System 6000 Fabric Card Chassis Hardware Installation Guide
164