Smart7 Additional Equipment Required; Table 8: Smart7 Recommended Fuse And Fuse Holders - Novatel SMART7 Installation And Operation Manual

High performance gnss receiver and antenna
Table of Contents

Advertisement

Chapter 2   SMART7 Installation Overview
3. Check that the Time Status is FINESTEERING which represents that time is fine set and
being steered.
4. Check the Receiver Status word (02004020 in this example). If the lowest bit (bit 0) is set,
the receiver has errors.
For information about the other digits in Receiver Status word, refer to the
RXSTATUS log in the

2.7 SMART7 Additional Equipment Required

In order for the SMART7 to perform optimally, the following additional equipment is required:
A computer (user supplied)
l
A cable harness for communicating with and powering the SMART7 (NovAtel SMART7 Inter-
l
face cable is available with four DB-9 connectors, six bare cables and a SMART7 connector
(refer to SMART7 Accessories and Replacement Parts on page 139
A fused power supply (user supplied)
l

Table 8: SMART7 Recommended Fuse and Fuse Holders

Fuse
12 V System Fuse
(standard size
blade)
12 V System Fuse
(mini size blade)
24 V System Fuse
High Reliability,
Harsh
Environment
(standard size
blade)
Inline Fuse
Holder, (for
standard size
blade)
Inline Fuse
Holder, (for mini
size blade)
SMART7 Installation and Operation User Manual 0C
Agriculture Commands and Logs Reference
Recommended Fuse/Fuse Holder
ATO Silver Blade Fuse 5 A (32 V) or
equivalent
Mini Blade Fuse 5 A (32 V) or equivalent
FKS ATO Blade Fuse 5A (80 V) or
equivalent
Waterproof ATO Fuse Holder