SMART7-I and SMART7-W Wi-Fi Configuration Overview
WIFIMODE OFF
3. Use the SAVECONFIG command to store the change in Non-Volative Memory.
This ensures the changes are kept when the receiver is restarted.
5.6 SMART7-I and SMART7-W ALIGN Over Wi-Fi Overview
ALIGN can be configured over Wi-Fi by the following methods:
SMART7-I and SMART7-W Automatic Wi-Fi ALIGN Corrections below
l
SMART7-I and SMART7-W Manual Set Up for Wi-Fi Connection between Master and Rover via
l
ICOM1 on the next page
Configure ALIGN Master on the next page
l
Configure ALIGN Rover on page 89
l
DHCP Configuration on page 89
l
Static IP Address Configuration on page 90
l
5.6.1 SMART7-I and SMART7-W Automatic Wi-Fi ALIGN Corrections
The WIFIALIGNAUTOMATION command is provided to simplify configuration of a pair of
NovAtel Wi-Fi enabled receivers, one acting as an ALIGN Master and one acting as an ALIGN
Rover.
The ALIGN Rover, acting as a Wi-Fi Client, connects to the specified Wi-Fi Access Point and con-
figures it as the ALIGN Master. Use the WIFIALIGNAUTOMATION command to configure.
WIFIALIGNAUTOMATION <enable_disable> <master_networkid> <icom_port> <data_
rate> <send_heading> <interface_mode>
Where:
enable_disable turns the feature on or off
l
master_networkid is the network ID associated with the SSID of the ALIGN Master as pre-
l
viously configured using the WIFINETCONFIG command.
icom_port is the ICOM port to be used for ALIGN corrections on both the Rover and the
l
Master. It is assumed that the Master's ICOM port is configured with its factory default set-
tings.
data_rate is as defined in the ALIGNAUTOMATION command.
l
interface_mode is as defined in the ALIGNAUTOMATION command.
l
The term passkey and password are the same.
If this feature is enabled and the SAVECONFIG command issued, when the Client is searching
for an Access Point (either after startup or if the connection is lost), it will connect to the Access
Point specified by <master_networkid> even if another Access Point with a preferred network_
id (as entered by the WIFINETCONFIG command) is in range.
SMART7 Installation and Operation User Manual 0C
87