Chapter 5 Built-In Status Tests

The Built-In Status Test monitors system performance and status to ensure the receiver is oper-
ating within specifications. The test detects an exceptional condition and informs the user
through one or more indicators. The receiver status system is used to configure and monitor the
indicators:
1. Receiver status word (included in the header of every message)

2. RXSTATUSEVENT log

3. RXSTATUS log

When a fatal event occurs (for example, a receiver hardware failure), a bit is set in the receiver
error word, part of the RXSTATUS log, to indicate the cause of the problem. An
RXSTATUSEVENT log is generated on all ports to show the cause of the error. Receiver track-
ing is disabled but command and log processing continues to allow error diagnosis. Even if the
source of the error is corrected, the receiver must be reset to resume normal operation.
5.1 RXSTATUSEVENT Log
The RXSTATUSEVENT log is used to output event messages, as indicated in the RXSTATUS
log.
On start up, the OEM7 receiver is set to log RXSTATUSEVENTA ONNEW on all ports. You can
remove this message using the UNLOG command.
Refer to the RXSTATUSEVENT log in the
log and command details. for a more detailed description of this log.
5.2 RXSTATUS Log
The Receiver Status log (RXSTATUS) provides system status and configuration information in a
series of hexadecimal words.

5.2.1 Status Word

The status word is the third field after the header, as shown in the example in Figure 26: Loca-
tion of Receiver Status Word below.