Novatel SMART7 Installation And Operation Manual page 49

High performance gnss receiver and antenna
Table of Contents

Advertisement

SMART7 Operation
2. Modify the log file settings.
File Path
File Name
Hold Type
File Split
3. Click the Save button.
SMART7 Installation and Operation User Manual 0C
The path of the directory in which the log files are stored.
Enter the path directly in the text box or click the Browse button and use the
dialog box to select the directory.
The file name used for the log file.
You can enter a name or allow NovAtel Connect to generate a name.
To enter a file name, clear the Auto check box and enter the name in the
text box.
The next logging session will save the logs using the entered name. For
subsequent logging sessions, you will be prompted whether you want to
replace the existing file or add the new session to the existing log file.
To allow NovAtel Connect to generate a unique name for each logging
session, ensure the Auto check box is selected. NovAtel Connect will
generate a new file for each logging session. The file is named with the
product serial number (PSN) and the time when the logging session started.
Enable or disable Hold on the logs started using the Logging Control Window.
When the Hold Type is set to No, the logs started using the Logging Control
Window can be unlogged when an UNLOGALL command is sent.
When the Hold Type is set to Yes, the logs started using the Logging Control
Window can not be unlogged when an UNLOGALL command is sent.
If a large amount of logging data is being collected, the data can be split into
multiple files by collection time or file size.
To enable file splitting, select the Enable check box and then select Time
and enter a value in hours or select Size and enter a value in MB.
49