Novatel SMART7 Installation And Operation Manual page 89

High performance gnss receiver and antenna
Table of Contents

Advertisement

SMART7-I and SMART7-W Wi-Fi Configuration Overview
interfacemode icom1 novatel novatelx off
movingbasestation enable
log icom1 novatelxobs ontime 1
log icom1 novatelxref ontime 1
log headinga onnew
saveconfig
Configure ALIGN Rover
The ALIGN rover can be configured to connect to the Master Access Point over Wi-Fi using either
DHCP (default) or by specifying static IP parameters. Configuration consists of the following
steps:
1. Establish a Wi-Fi connection from the Rover (Client) to the Master (Access Point).
2. Establish a TCP connection between the ICOM port to be used for ALIGN corrections and the
Access Point.
3. Configure the interface of the ICOM port to accept ALIGN corrections.
In the following examples, the ALIGN Rover is configured as a Wi-Fi Client connecting to the
Master's Access Point. The Master's SSID is "PwrPak7-NMND17190003B", its password (pass-
key) is "12345678" and its IP address is the default 192.168.19.1. The SSID and password (pass-
key) information is printed on the label of the Master receiver or it can be obtained by
requesting the WIFIAPSETTINGS log from the Master. The SSID is the receiver's PSN starting
with the SM7-prefix.
DHCP Configuration
In this example, the WIFINETCONFIG command is used to enable the Client to connect to the
Master's Access Point using DHCP addressing. The IPSTATUS log is used to determine when an
IP address has been assigned to the Wi-Fi client.
It can take several seconds for the IP parameters to be set.
wifinetconfig 1 enable "PwrPak7-NMND17190003B" "12345678" dhcp
wifimode client
icomconfig icom1 tcp 192.168.19.1:3001
interfacemode icom1 novatelx novatel off
log icom1 headingext2b onnew
hdtoutthreshold 1.0
log headinga onnew
saveconfig