Poe Status Leds; Table 10: Poe Status Leds - Allied Telesis AT-IE300-12GP Installation Manual

Ie300 series. industrial ethernet switches
Hide thumbs Also See for AT-IE300-12GP:
Table of Contents

Advertisement

PoE Status LEDs

Table 9. SFP Slot LED (Continued)
State
Flashing Amber
Off
The following notes apply to the PoE Status LEDs:
The switch uses 240W as the default nominal PoE budget for the
Optimal, 50%, 80%, and 90% PoE Status LEDs. The LEDs might
not reflect the true wattage usage of the powered devices if the
actual PoE budget from the power supply is different. You can
adjust the nominal budget with the POWER-INLINE WATTAGE
MAX command in the Global Configuration mode of the operating
system. For instructions, refer to "Configuring the Provisioned PoE
Budget" on page 104.
Do not operate the switch if the Overvolt LED is solid amber. Either
the power supply is generating too much power or it is not
compatible with the switch. Turn off and replace the power supply.
The LEDs do not indicate the presence of Hi-PoE devices. To
check for Hi-PoE devices, use the SHOW POWER-INLINE
command in the User Exec or Privileged Exec mode. Devices
using more than 25.9W are considered Hi-PoE devices.
The PoE status LEDs on the AT-IE300-12GP Switch are defined in
Table 10.
LED
State
Overvolt
Solid Amber
Off
The port is transmitting or receiving
network packet traffic at 100Mbps.
The port has not established a link to a
network device.
Table 10. PoE Status LEDs
The DC power from the power supply
exceeds the maximum limit for the switch.
The power supply should be replaced.
The DC power from the power supply is
within the normal operating range of the
switch.