DataView™ LI55 Level Controller
Instruction Manual
Tare ( tArE )
The tare function zero's out the display. In the case of scale weight, tare is used
to eliminate container weight and provide net weight readings. There are two tare
functions; Capture Tare and Reset Tare.
When the capture tare function is used, the display reading is offset by the
displayed amount to make the displayed value zero. This modified display value
is the net value. The originally displayed value without the tare offset is the gross
value. Both may be chosen as a display option.
Reset tare removes the display offset of the net value, and the gross and net
values become the same until a new capture tare is entered.