Enabler Uninstall Process

Enabler Uninstall Process
To remove the LXE Avalanche Enabler from the MX7 Tecton:
Delete the Avalanche folder located in the \System directory.
l
Warm boot the MX7 Tecton.
l
The Avalanche folder cannot be deleted while the Enabler is running. See
If sharing errors occur while attempting to delete the Avalanche folder, warm boot the MX7 Tecton, immediately delete the
Avalanche folder, and then perform another warm boot.

Stop the Enabler Service

To stop the Enabler from monitoring for updates from the Mobility Center Console:
1. Open the Enabler Settings Panels by tapping the Enabler icon on the MX7 Tecton desktop.
2. Select File | Settings.
3. Select the Preferences tab.
4. Select Do not monitor to prevent automatic monitoring upon startup.
5. Select Exit Application for an immediate shutdown of all Enabler update functionality upon exiting the user interface.
6. Click the OK button to save the changes.
7. Reboot the MX7 Tecton if necessary.

Update Monitoring Overview

There are three methods by which the Enabler on the MX7 Tecton can communicate with the Mobile Device Server running on
the host machine.
Wired via a serial cable between the Mobile Device Server PC and the MX7 Tecton.
l
Wired via a USB connection, using ActiveSync, between the Mobile Device Server PC and the MX7 Tecton.
l
Wirelessly via the MX7 Tecton 802.11 radio and an access point
l
After installing the Enabler on the MX7 Tecton the Enabler searches for a Mobile Device Server, first by polling all available
serial ports and then over the wireless network.
The Enabler running on the MX7 Tecton will attempt to access COM1, COM2, and COM3. "Agent not found" will be reported if
the Mobile Device Server is not located or a serial port is not present or available (COM port settings can be verified using the
LXE scanner applet in the Control Panel on the MX7 Tecton).
The wireless connection is made using the default wireless [radio] interface on the mobile device therefore the MX7 Tecton
must be actively communicating with the network for this method to succeed.
If a Mobile Device Server is found, the Enabler automatically attempts to apply all wireless and network settings from the
active profile. The Enabler also automatically downloads and processes all available packages.
If the Enabler does not automatically detect the Mobile Device Server, the IP address of the Mobile Device Server can be
entered on the Connect tab of the Enabler setup. Please see
E-EQ-MX7CERG-A [ 215  ] MX7 Tecton™ CE Reference Guide
Stop the Enabler
Enabler Configuration
for details.