Running Protocol Tests - Using the Front Panel GUI

This section provides the Instructions for Use for the running the HDMI protocol tests. Refer to Table 9-1 above for specific
examples for setting the options.
Note: If the 804/804A/804B is used in a manner not specified in the guide, the protection provided by the equipment may be
impaired.
12.1

Testing HDMI Protocols

You can test HDMI protocols (such as HDCP, EDID and CEC) on an HDTV or A/V Receiver.
Note: Only the 804B supports HDCP 2.2 authentication testing.
12.1.1
Procedures for Testing HDMI-HDCP 1.4 protocol on an HDTV
Use the following procedures to run HDCP test on an HDTV.
1.
Power up the 804/804A using the rocker switch on the back panel and the front panel. The On position is with the toggle
switch depressed on the inner side of the switch. Refer to the procedures in Chapter entitled:
2.
From the main menu screen (shown below), touch select Tests.
3.
Select HDCP Test from the Sink Tests menu shown below.