DVQM 2
// sets the mode or range to 16-235).
or
DVQM 0
// sets the mode or range to 0-255).
DVQM?
// returns the current value.
DVSM
Command supported?: Y
Sets the sampling mode between 4:4:4 and 4:2:2 in YCbCr mode on HDMI. Valid values are: 2 = 4:2:2; 4 = 4:4:4.
Requires FMTU or ALLU to activate.
Query returns the current setting of the digital sampling mode.
Examples:
DVSM 2
// sets the sampling to 4:2:2.
or
DVSM 4
// sets the sampling to 4:4:4.
DVSM?
// returns the current value.
DVST
Command supported?: Y
Sets the digital video signal type. Valid values are: HDMI/DVI RGB = 10; HDMI YCbCr = 14.
Requires FMTU or ALLU to activate.
Query returns the current setting of the digital video signal type.
Example:
DVST 10
// activates the HDMI/DVI output for RGB video).
DVST?
// returns the current value.
EQUA
Command supported?: Y
Sets how many lines of equalization come after VSYNC.
Requires FMTU or ALLU to activate.
Query returns the current setting for the number of lines of equalization.
Example:
EQUA 1
// sets the equalization to 1 line after vsync.
EQUA?
// returns the current value.
EQUB
Command supported?: Y
Sets how many lines of equalization come before VSYNC.
Requires FMTU or ALLU to activate.
Query returns the current setting for the number of lines of equalization.
Example:
EQUB 2
// sets the equalization to 2 line before vsync.
EQUB?
// returns the current value.