Device-dependent Errors (continued)
115
Output track resistance out of range
The output track resistance is out of range. Re-calibrate the output module.
116
Locked out by internal switch setting
This function has been locked out by an internal switch in the mainframe.
117
Calibration error
A calibration error has occurred. Do not save calibration constants. Try re-calibrating the unit.
200
Hardware error channel <channel>
A hardware error has occurred on the specified channel.
201
Invalid configuration, empty slots
There is an empty slot between modules. This configuration is not allowed.
202
Selftest Fail
A selftest failure has occurred. See selftest failure list for details.
203
Compatibility function not implemented
The requested compatibility function is not available.
204
NVRAM checksum error
A checksum error has occurred in the instrument's nonvolatile random access memory.
205
NVRAM full
The nonvolatile random access memory of the instrument is full.
206
File not found
The internal calibration file or the internal channel attribute file was not found in NVRAM.
207
Cal file version error
The calibration file was written or read using old firmware. Firmware must be updated.
208
Running backup firmware
The instrument is presently running the backup (previous) version of the firmware.
209
Modules do not match group NV config
One or more modules that have their output coupled do not match the instrument state settings.
210
Frame NVRAM error
A non-volatile RAM error has occurred in the mainframe
211
Output state couple modules do not match
One or more modules in the group does not match the non-volatile configurations settings.
302
Option not installed
The option that is programmed by this command is not installed.
303
There is not a valid acquisition to fetch from
There is no valid data in the measurement buffer.
304
Volt and curr in incompatible transient modes
Voltage and current cannot be in Step and List mode at the same time.
305
A triggered value is on a different range
A triggered value is on a different range than the one that is presently set.
306
Too many list points
Too many list points have been specified.
307
List lengths are not equivalent
One or more lists are not the same length.
308
This setting cannot be changed while transient trigger is initiated
Setting cannot be changed while the instrument is waiting for or executing a trigger sequence.
309
Cannot initiate, voltage and current in fixed mode
Cannot initiate the transient generator. Either the voltage or the current function is set to Fixed
mode.
310
The command is not supported by this model
This power modules either does not have the hardware capability or the options required to
support this command.
Model N6705 Service Guide
Error Messages
Appendix A
127