S5-115F Manual
7.4

Configuring the Hardware with COM 115F

This section contains the configuration screen forms for the I/O types mentioned in the example.
Configuring hardware with COM 115F means
Selecting an I/O type for each input or output
Defining characteristics at these inputs/outputs
Defining signal groups, check addresses and data blocks for the configuration data.
Configuring the single-channel digital input modules
Call the configuration form for I/O type 1
Select DI word 32 with the cursor control keys
Enter type no. "1" in the field for bit 32.0 and terminate the input with <Return>
The cursor jumps to the configuration field
Enter the following in the configuration field
DB number
(4 to 255):
SUBUNIT
(A/B): B
Repeat the entries for addresses 32.1 to 35.7
(You can copy the configuration data of bit 32.0 also to addresses 32.1 to 35.7 1.2.2).
Figure 7-5 shows the finished entries.
I/O type 1
S5-115F:
Configuring the I/O Modules
Bits
DI-W
32
DI-W
34
Digital input
Type number
Num. of I/O Channels
Safety rel.
Status:
TYPE INPUT
F1
SEARCH
Save your configuration data on the default program file by pressing F6
Terminate the input by pressing F8
EWA 4NEB 811 6149-02
11
0
1
2
3
4
5
1
1
1
1
1
1
1
1
1
1
1
1
32.0
: 1
DB number
: 1
SUBUNIT
: No
F2
F3
F4
COPY
SWAP
DELETE
Figure 7-5. Initialization Screen Form for I/O Type 1
COM 115F / PDC15
6
7
0
1
2
3
1
1
1
1
1
1
1
1
1
1
1
1
(4-255):
(A/B): B
F5
F6
TYPES
SAVE
Application
4
5
6
7
1
1
1
1
1
1
1
1
11
F7
F8
RETURN
7-7

Advertisement

Table of Contents
loading