Table 1-8. COM 115F Configuration Error Messages (Continued)
Error Text
SUBUNIT NOT YET DEFINED
SOURCE WITHIN DESTINATION
DESTINATION WITHIN SOURCE
INVALID BYTE NUMBER
INVALID WORD NUMBER
WRONG PLC MODE
NO ERROR FOUND
DISKETTE ERROR
FILE NOT AVAILABLE
NO CONNECTION TO PLC
DB NOT AVAILABLE
NO CONFIGURATION DB
WRONG CONFIGURATION DB
EPROM ALREADY SIGNED
ILLEGAL TYPE MIX
WRONG TYPE MIX IN FEEDBACK
ONLY 15 NODES PERMITTED
ILLEGAL: OVERLAP
FLAGS BEYOND 255
MESSAGE XY
EWA 4NEB 811 6149-02
Cause of Error
Subunit identifier not yet in
PLC
Invalid ranges or numbers for
searching, copying, exchang-
ing and deleting
The ISTACK in the PLC cannot
be read
No error found during F error
output
Occurs when reading from or
writing to diskette
Occurs when reading or
writing from PLC
Configuration DB missing or
wrong
Attempt to sign a signed
EPROM
Configuration rules have not
been followed
Occurs if an attempt is made to
configure a mailbox table for
the 16th node in a redundant
SINEC L1 LAN
Overlap of the mailboxes of
several nodes
Flag address+mailbox > 255
PLC interface error message
Configuring with COM 115F
Explained in
1.1
1.2.2
1.2.2
1.2.2
1.2.2
1.1.5
1.1.5
1.1.7, 1.2.2
1.1.7
1.1.7
1.1.7
1.1.7
1.1.7
1.1.7
1.1.7, 1.2
1.1.7, 1.2
1.1.2
1.1.2
1.1.2
Refer to your programmer
manual.