S5-115F Manual
Error
Con-
Error Message Text
Identi-
sec.
fier
No.
Progr.
252
01
FB 252 called with wrong
parameters:
Programming error
252
02
CP 523 module address
wrong:
Additional info 1:
Module address
252
03
AI module not configured as
CP 523:
Configuration error
252
04
Wrong character entered for
function:
Programming error
Additional info 1:
Wrong character
252
05
Data block missing:
Handling error
Additional info 1
DB number
EWA 4NEB 811 6149-02
Possible Cause
Error group No. 12
Error group No. 12
-
FB 252 wrongly initialized
Error group No. 12
-
Wrong configuration
Error group No. 12
-
FB 252 wrongly initialized
Error group No. 12
-
Data block specified is outside
permissible range
(>3 und <256)
DB No. entered
Decimal display
PLC Error Messages
Remedy
-
Correct FB 252 call
-
Check parameters
Warm restart:
1. Stop/Run
-
Check parameters
Warm restart:
1. Stop/Run
-
Check configuration
Warm restart:
1. Stop/Run
-
Check parameters
Warm restart:
1. Stop/Run
-
Check FB 252 parameters
Warm restart:
1. Stop/Run