13.3
Range
Accuracy
Laser dot size
Characteristics
13.4
Telescope
Compensation
Level
Technical Data
Distance Measurement without Reflectors
(Non-Prism mode)
Kodak Gray Card
White side
90% reflective
Grey side
18% reflective
*
The distance range can vary depending on the conditions and can
be above or below the specified value. The specified range value is
referring to non-extreme conditions, visibility about 20 km, moder-
ate sunlight, slight heat shimmer.
Standard measuring 3 mm + 2 ppm
>200m
Beam interruptions, severe heat shimmer and moving objects within the beam
path can result in deviations of the specified accuracy and measurement time.
Distance [m]
at 50
Type
Principle
Type
Carrier wave
Measuring system

General Technical Data of the Product

Type
All-around rotation
Magnification
Objective diameter
Focusing range
Field of view
Field width at 100 m
Compensator range: ±8'
Type
Longitudinal level sensitivity
[m]*
500
200
ISO17123-4
5 mm + 3 ppm
Laser dot size, approximately [mm]
12 × 24
Description
Phase measurement
Coaxial, visible red laser
685 nm
Phase surveying about 75 MHz (74.926925 MHz)
Value
28 x
44 mm
1.50 m/4.92 ft to infinity
1°30'/1.66 gon
2.8 m
Value
2'/2 mm
[ft]*
1640
820
Measure time, typical [s]
1.1 in Quick mode
1.4 in Standard mode
-
95