Distance Measurement Without Reflectors - Leica TS12P User Manual

Robotic total station
Table of Contents

Advertisement

7.3
Range
Atmospheric condi-
tions
Accuracy
Characteristics
Laser dot size
TS12P, Technical Data

Distance Measurement without Reflectors

Type
Kodak Gray
Card
R400
White side, 90 %
reflective
R400
Grey side, 18 %
reflective
R1000
White side, 90 %
reflective
R1000
Grey side, 18 %
reflective
Range of Measurement:
Display unambiguous:
D:
Object in strong sunlight, severe heat shimmer
E:
Object in shade, sky overcast
F:
Underground, night and twilight
Standard measuring
0 m - 500 m
>500 m
*1 does not include radio transfer time to the CS.
Object in shade, sky overcast. Beam interruptions, severe heat shimmer and moving
objects within the beam path can result in deviations of the specified accuracy. The
display resolution is 0.1 mm.
Type:
Carrier wave:
Measuring system:
Distance [m]
at 30
at 50
at 100
Range D
[m]
[ft]
200
660
150
490
800
2630
400
1320
1.5 m - 1200 m
up to 1200 m
std. dev.
Measure time,
typical [s]
ISO 17123-4
2 mm + 2 ppm
3 - 6
4 mm + 2 ppm
3 - 6
Coaxial, visible red laser
658 nm
System analyser basis 100 MHz - 150 MHz
Laser dot size, approximately [mm]
7 x 10
8 x 20
16 x 25
Range E
Range F
[m]
[ft]
[m]
300
990
>400
200
660
>200
1000
3280
>1000
500
1640
>500
Measure time,
maximum [s]*
12
12
[ft]
>1310
>660
>3280
>1640
1
59

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents