Characteristics
7.3
Range
Atmospheric condi-
tions
Technical Data
Distance meas-
std. dev.
uring mode
ISO 17123-4,
standard prism
Once
1 mm + 1.5 ppm
Once & fast
2 mm + 1.5 ppm
Continuously
3 mm + 1.5 ppm
Repeatedly &
1 mm + 1.5 ppm
average
Beam interruptions, severe heat shimmer and moving objects within the beam
path can result in deviations of the specified accuracy.
The display resolution is 0.1 mm.
Type
Principle
Type
Carrier wave
Measuring system

Distance Measurement without Reflectors

(Non-Prism mode)

Pinpoint R500 (without reflector)
Kodak Gray Card
White side
90% reflective
Grey side
18% reflective
Pinpoint R1000 (without reflector)
Kodak Gray Card
White side
90% reflective
Grey side
18% reflective
Range of measurement:
Display unambiguous:
Range
Description
D
Object in strong sunlight, severe heat shimmer
E
Object in shade, or overcast
F
Underground, night and twilight
std. dev.
ISO 17123-4,
tape
3 mm + 2 ppm
3 mm + 2 ppm
3 mm + 2 ppm
1 mm + 1.5 ppm
Description
Phase measurement
Coaxial, visible red laser
658 nm
System Analyzer Basis 100 MHz - 150 MHz
Range D
Range E
[m]
[ft]
[m]
250
820
500
100
330
150
Range D
Range E
[m]
[ft]
[m]
800
2630
1000
400
1320
500
1.5 m to 1200 m
up to 1200 m
Measurement
time, typical [s]
2.4
2.0
< 0.15
-
Range F
[ft]
[m]
[ft]
1640
>500
>1640
490
>200
>820
Range F
[ft]
[m]
[ft]
3280
>1000
>3280
1640
>500
>1640