Logic And Alarm Functions - JUMO IMAGO F3000 Operating Instructions Manual

Process controller for the meat processing industry
Hide thumbs Also See for IMAGO F3000:
Table of Contents

Advertisement

7.7.7 Logic and alarm functions

Function
Text
Delay
Message
Alarm
IMAGO F3000 / 10.01
Logic signals or a probe break can trigger various events and messages which
are defined here.
The following signals can be assigned to logic and alarm functions:
- Probe break
- Logic inputs
- Limit comparators
- Logic modules
- Control contacts
- Others (program end, program lock, equipment/operating hours counter)
Selection/settings
No function
Keypad lock
Keypad lock, except Start/Stop
Lock configuration
Lock process steps
Lock programs
Program start
Program stop
Cancel program
Next segment
Previous segment
Door contact
Standard text
Text 1 — 100
No text
0 — 9999 sec
(active)
(inactive)
(active)
(inactive)
k
/ bold = factory setting
7 Setup Program
Description
The event that is to be triggered
Door contact:
Timebase on hold, all relays OFF,
analog outputs = 0
The text to be displayed on the screen.
Standard text:
An appropriate text that is stored in the instrument
Text 1 — 100:
Freely defined user texts, system texts
h Change to menu item "User texts"
with (...)
A message or alarm is generated after a delay (in
seconds).
A message is generated.
An alarm message is generated.
79