7.5.3 Smoke generator

Control contact
Ignition time
Time for one turn
Max. pause time
Description
Configuration
IMAGO F3000 / 10.01
Two smoke generators can be configured. The parameters for the conveyor
screw can only be set for smoke generator 1.
Selection/settings
(Logic selector)
OFF
0 — 9999sec
0 — 8 — 9999sec
0 — 9999 sec
k
/ bold = factory setting
The smoke generator is activated by a control function. Two outputs operate
the ignition of the sawdust and its transport (only for smoke generator 1).
While the program is running, the smoke intensity can be regulated by entering
a setpoint W
in the program.
SMOKE
h Assign names to the control functions for operating the smoking and saw-
dust ignition
Edit
Setup-only settings
h Define a process step "Smoke"
- Set values to activate the control functions
- Define the smoke intensity as a preset value, if such a parameter is
to be used
h Assign the logic outputs for "Smoke generator ignition" and "Intensity,
smoke generator 1" and the setting for the ignition time
7 Setup Program
Description
Logic signal used to activate the smoke generator.
Duration of the ignition for the smoke generator.
The time that the conveyor screw (for sawdust)
requires to make a single turn.
The time after which sawdust needs to be fed in
again.
Names
73