Setup-Only Settings; 7-Segment Displays; Function Keys - JUMO IMAGO F3000 Operating Instructions Manual

Process controller for the meat processing industry
Hide thumbs Also See for IMAGO F3000:
Table of Contents

Advertisement

End : date
End : time
7.7

Setup-only settings

7.7.1 7-segment displays

Display 1 — 3
Display 4

7.7.2 Function keys

IMAGO F3000 / 10.01
Selection/settings
DD.MM.YYYY
28.10.2001
00:00:00 — 23:59:59
03:00:00
k
/ bold = factory setting
The values which are displayed on the four 7-segment displays can be config-
ured.
Display 1 — 4
Selection/settings
(Analog selector)
1
Analog input 1
2
Analog input 3
3
Relative humidity
Remaining segment time
Program run-time
Remaining program time
k
/ bold = factory setting
1. factory setting for display 1
2. factory setting for display 2
3. factory setting for display 3
The 12 freely assignable function keys can be assigned to various control and
display functions.
Function keys 1 — 12
Function
No function
Next segment
Previous segment
Previous program
Process step
7 Setup Program
Description
Date for automatically changing back from summer
time
Time for automatically changing back from summer
time
Description
The values which can be displayed in the displays
1 — 3.
Time remaining until the end of the segment
Time since the start of the program
Time remaining until the end of the program
Since not all the program segments are under time-
control, it is not possible to give a 100% precise
value for the remaining program time. The
complete (remaining) program time is derived by
using the previous run of the program as a
reference.
Description
The key does not have a function.
In automatic operation: the program
continues from the next segment
(entry on the instrument).
In automatic operation: the program
goes back to the previous segment
(entry on the instrument).
Starts the last program that was run
previously, from the basic status.
Calls up the current process step.
75

Advertisement

Table of Contents
loading

Table of Contents