7.2.2 Editing process steps

Switching action
Function
Control function
time
ON pulse time
OFF pause time
IMAGO F3000 / 10.01
Control contacts
This defines whether a control contact is active during this process step, and
which type of switching action it follows.
Selection/settinge
No response
Switching is activated
Direct action
Switch-on delayed
Switch-off delayed
Switch-on advanced
Switch-off advanced
Stop delay
Start and stop delay
0 — 32767sec
0 — 32767sec
0 — 32767sec
k
/ bold = factory setting
7 Setup Program
Description
Defines whether a control contact should use a
specific type of switching action.
T
= control function time
s
see above
Defines a pulse action while the contact is active,
always starting with T
ON
Example ("Direct"):
T
= ON pulse time
ON
Stop delay:
Start and stop delay:
T
= OFF pause time
OFF