Mounting - JUMO IMAGO F3000 Operating Instructions Manual

Process controller for the meat processing industry
Hide thumbs Also See for IMAGO F3000:
Table of Contents

Advertisement

3 Installation

3.2 Mounting

Front panel
cut-out
Close mounting
Care of the
front panel
A
12
h (1) Insert the instrument from the front into the front panel cut-out
h (2) From the back of the panel, push the mounting brackets into the guide
slots on the sides of the housing
h (3) Use a screwdriver to tighten up the mounting brackets evenly
If several instruments are mounted in the same front panel, either above one
another or side-by-side, then a minimum spacing of 35 mm must be allowed
between each cut-out in the panel.
The front panel can be cleaned with normal commercial detergents and clean-
ing agents. It is resistant to organic solvents (such as ethyl alcohol, turpentine
substitute, P1, xylol and the like).
It is not resistant to corrosive acids or lyes, abrasives, or cleaning
with high-pressure cleaners!
IMAGO F3000 / 10.01