Program Source - JUMO IMAGO F3000 Operating Instructions Manual

Process controller for the meat processing industry
Hide thumbs Also See for IMAGO F3000:
Table of Contents

Advertisement

7 Setup Program

7.4.6 Program source

Restart after
power interruption
Program end time
Chamber
Core
Pulse time for
humidity control
Segment step-on
core/time
Value range
68
Various parameters that influence the running of the program are set here.
General
Selection/settings
Cancel program
Continue from interruption
Standstill
Continue at X % chamber
temp.
0 — 60 — 9999sec
Process value signals
(Analog selector)
1
Analog input 1
2
Analog input 3
0 — 5 — 9999sec
Core OR time
Core AND time
k
/ bold = factory setting
1. factory setting for chamber
2. factory setting for core
Setpoint limits
Limits can be defined for the setpoint entry on the instrument.
The range of values for all setpoints is 0 — 999.
Description
The program is canceled:
The present program is canceled at the point
of the power interruption.
The instrument is then in the basic status.
Continue:
The instrument continues the program auto-
matically from the point where the interruption
occured.
Standstill:
When power returns, the program remains in
standstill at the point where the interruption
occured. "Standstill" appears in the alarm line.
The program can be canceled or continued
from the keyboard.
Continue at X % chamber temp.
If the difference between the actual tempera-
ture in the chamber before and after the power
interruption is no larger than this % value, then
the program continues automatically. If the dif-
ference is larger, then the instrument responds
as for standstill.
Duration of the program end signal
v Chapter 7.7.6 "Assignment of the relay out-
puts"
Signal sources for chamber and core temperatures
If the actual value (process value) in the chamber
goes beyond the measuring range limits, all
controllers will be switched off.
The ON time for the humidifier.
The pause (OFF) time is entered in the program
v Chapter 6.2.2 "Program entry"
Condition for stepping on to the next segment:
Reaching the core setpoint AND/OR elapse of the
segment time.
IMAGO F3000 / 10.01