9
MAINTENANCE
■ Troubleshooting
PROBLEM
Transmitting is impossible.
A Program Scan does not
start.
A Memory Scan does not
start.
33
BASIC MANUAL
POSSIBLE CAUSE
• The transmit power level is set to
S-LOW, LOW 1, LOW 2 or MID.
• The PTT Lock function is activated.
• The Busy Lockout function is activated.
• The transmit frequency is out of the
amateur radio band.
• The VFO mode is not selected.
• The same frequencies are entered into
the scan edges.
• The Memory mode is not selected.
• Only one or no memory channel is
entered.
SOLUTION
• Set the transmit power level to HIGH.
• Turn OFF the PTT Lock function on
the MENU screen.
• Turn OFF the Busy Lockout function
on the MENU screen.
• Set the transmit frequency within the
amateur radio band.
• Push [V/MHz] to select the VFO mode.
• Enter different frequencies into the
scan edges.
• Push [M/CALL] to select the Memory
mode.
• Enter two or more memory channels.
REF.
p. 18
p. 69
p. 69
pp. 17, 18
p. 13
ADVANCED
MANUAL
(Section 8)
p. 13
p. 21
Need help?
Do you have a question about the ID-31E PLUS and is the answer not in the manual?
Questions and answers