MAINTENANCE
■ Troubleshooting
PROBLEM
Transmitting is impossible.
A Program Scan does not
start.
A Memory Scan does not
start.
33
BASIC MANUAL
POSSIBLE CAUSE
• The transmit power level is set to
S-LOW, LOW 1, LOW 2 or MID.
• The PTT Lock function is activated.
• The Busy Lockout function is activated.
• The transmit frequency is out of the
amateur radio band.
• The VFO mode is not selected.
• The same frequencies are entered into
the scan edges.
• The Memory mode is not selected.
• Only one or no memory channel is
entered.
SOLUTION
• Set the transmit power level to HIGH.
• Turn OFF the PTT Lock function on
the MENU screen.
• Turn OFF the Busy Lockout function
on the MENU screen.
• Set the transmit frequency within the
amateur radio band.
• Push [V/MHz] to select the VFO mode.
• Enter different frequencies into the
scan edges.
• Push [M/CALL] to select the Memory
mode.
• Enter two or more memory channels.
REF.
p. 18
p. 69
p. 69
pp. 17, 18