DVC6000f Digital Valve Controllers
DVC6000f Troubleshooting Checklist
Reference
1. Instrument serial number as read from nameplate _________________________________________
2. What is the firmware version of the DVC6000f? _________________
3. What is the hardware version of the DVC6000f? ________________
4. What is the Diagnostic Tier of the DVC6000f? FD___ AD___ PD___
5. What is the Control Tier of the DVC6000f? SC___ FL___ FC___
6. What is the address of the DVC6000f? ________________________
Mode and Status
7. What are the DVC6000f Block Modes?
Actual Modes:
Target Modes:
Permitted Modes: Resource Block _____ Transducer Block_____ Analog Output Block _____
8. What is the status of the individual function blocks?
Operational
9. Does the digital valve controller respond to the control signal? Yes _________ No _________
If No, describe
10. Is it on Travel or Pressure control?
7
11. What are the following parameter readings?
Setpoint _________
Supply Pressure _________
Travel Target _________%
12. What is the safe position of the valve? Fail Closed ____ Fail Open ____
Interface and Diagnostic Tools
13. What interface and diagnostic tools are available?___________________________________
14. Provide any available supporting documentation, such as Status Monitor, Detailed Setup, any alert readings.
Mounting
Reference
1. Actuator application:
2. Which digital valve controller do you have?
Remote mount digital valve controller?
3. What Make, Brand, Style, Size, etc. actuator is the DVC6000f mounted on? _________________________
Operational
4. What is the full travel of the valve?__________________________________
5. What is the Mounting Kit part number? ______________________________
Other
6. If mounting kits are made by LBP/Customer, please provide pictures of installation.
7. For a DVC6010f or a DVC6030f: During full travel of the actuator, does the DVC6000f feedback arm move
below the "A" or above the "B" alignment positions? (It should not) Yes____ No ____
7-20
Resource Block _____ Transducer Block_____ Analog Output Block _____
Resource Block _____ Transducer Block_____ Analog Output Block _____
Drive Signal _________%
Pressure A _________
Travel _________%
Sliding Stem? ____ Rotary? ____
DVC6005f with DVC6010f ____ DVC6020f ____ DVC6030f____
Pressure B _________
Pressure B _________
DVC6010f ____ DVC6020f ____ DVC6030f____
or,
December 2009
Need help?
Do you have a question about the Fisher FIELDVUE DVC6000f and is the answer not in the manual?
Questions and answers