DVC6000f Digital Valve Controllers
Transducer Block Parameter List
D Read/Write Capability: RO − Read Only, RW − Read Write
D Mode: The block mode(s) required to write to the parameter
D Protection Category: Indicates whether or not the parameter is writable while the PROTECTION parameter
is set to a particular level.
−N/A indicates a read-only parameter that is never writable, regardless of the value of the PROTECTION parameter
−NONE indicates a read-only parameter that is always writable, regardless of the value of the PROTECTION parameter
−CAL indicates a parameter that is only writable while the value of the PROTECTION parameter is "NONE".
−SETUP indicates a parameter that is only writable while the value of the PROTECTION parameter is "NONE" or "CAL".
−ALL indicates a parameter that is writable while the value of the PROTECTION parameter is "NONE", "CAL", or "SETUP & CAL".
D Double indentation and shaded Index Number indicates sub-parameter
4
Label
PARAMETER_NAME
Static Revision
ST_REV
Tag Description
TAG_DESC
Strategy
STRATEGY
Alert Key
ALERT_KEY
Block Mode
MODE_BLK
TARGET
ACTUAL
PERMITTED
NORMAL
Block Error
BLOCK_ERR
Update Event
UPDATE_EVT
UNACKNOWLEDGED
UPDATE_STATE
TIME_STAMP
STATIC_REVISION
RELATIVE_INDEX
4-42
Table 4-13. Transducer Block Parameter Definitions
Index
RO /
Mode
Range
Number
RW
1
RO
N/A
0 to 65535
2
RW
ALL
3
RW
ALL
0 to 65535
4
RW
ALL
1 to 255
5
5.1
RW
ALL
5.2
RO
N/A
3: AUTO
4: MANUAL
5.3
RW
ALL
7: OOS
5.4
RW
ALL
3: Simulate Active
10: Static Memory
Failed (Functional or
thermal data missing)
6
RO
N/A
13: Maintenance
Needed Now
(Functional or thermal
data missing)
15: Out-of-Service
7
0=Undefined
7.1
RW
ALL
1=Acknowledged
2=Unacknowledged
0=Undefined
1=Updated reported
7.2
RO
N/A
2=Update Not reported
7.3
RO
N/A
7.4
RO
N/A
7.5
RO
N/A
−Continued−
Protect
Initial Value
Category
Data Type: Uint16
The revision level of the static data.
Increments by one each time a
N/A
N/A
static parameter is written. The
value is reset to 0 whenever a
Restart with Defaults is performed.
See Restarting the Instrument.
Data Type: String
NULL
SETUP
The description of the block.
Data Type: Uint16
0
SETUP
Used to help group blocks.
Data Type: Uint8
The identification number of the
plant unit. Devices in a loop or plant
1
SETUP
section can be assigned with a
common alert key to aid the
operator in determining location of
alerts.
Data Type: DS-69
The actual, target, permitted, and
normal modes.
7: OOS
NONE
Target: The requested block
mode
N/A
N/A
Actual: The current mode of
3:AUTO
the block
4:MANUAL
NONE
Permitted: Allowed modes for
7: OOS
Target
Normal: Most common mode
3:AUTO
NONE
for Target
Data Type: Bit String (2 byte)
Error status associated with
N/A
N/A
hardware or firmware for the
transducer block.
0
NONE
Data Type: DS-73
0
N/A
Alert generated by change to static
data.
0
N/A
0
N/A
0
N/A
Description