Emerson Fisher FIELDVUE DVC6000f Instruction Manual page 123

Digital valve controllers
Hide thumbs Also See for Fisher FIELDVUE DVC6000f:
Table of Contents

Advertisement

Label
PARAMETER_NAME
Temperature Units
TEMPERATURE_UNITS
Pressure Units
PRESSURE_UNITS
Travel Units
TVL_UNITS
Length Units
LENGTH_UNITS
Area Units
AREA_UNITS
Spring Rate Units
SPRING_RATE_UNITS
MAI_CHANNEL_MAP
MAI Channel 1
MAI_CHANNEL_1
MAI Channel 2
MAI_CHANNEL_2
MAI Channel 3
MAI_CHANNEL_3
MAI Channel 4
MAI_CHANNEL_4
MAI Channel 5
MAI_CHANNEL_5
MAI Channel 6
MAI_CHANNEL_6
MAI Channel 7
MAI_CHANNEL_7
MAI Channel 8
MAI_CHANNEL_8
Output Block Selection
OUTBLOCK_SEL
PlantWeb Alerts Set PV Status
PWA_SET_STATUS
Block Information
BLOCK_INFO
Reserved B
RESERVED_B
Travel Always
TRAVEL_ALWAYS
December 2009
Table 4-13. Transducer Block Parameter Definitions (Continued)
Index
RO /
Mode
Range
Number
RW
C=1001
89
RW
ALL
F=1002
kPa=1133
bar=1137
psig=1143
90
RW
ALL
inHg=1155
inH2O=1146
2
Kg/cm
=1145
cm=1012
mm=1013
91
RW
ALL
in=1019
deg=1005
cm=1012
92
RW
ALL
mm=1013
in=1019
2
cm
=1025
2
93
RW
ALL
mm
=1027
2
in
=1030
N/m=1165
94
RW
ALL
lb/in=1596
95
MAN,
95.1
RW
1 through 13
OOS
MAN,
95.2
RW
1 through 13
OOS
MAN,
95.3
RW
1 through 13
OOS
MAN,
95.4
RW
1 through 13
OOS
MAN,
95.5
RW
1 through 13
OOS
MAN,
95.6
RW
1 through 13
OOS
MAN,
95.7
RW
1 through 13
OOS
MAN,
95.8
RW
1 through 13
OOS
MAN,
1: AO Block
96
RW
OOS
2: DO Block
MAN,
1: No
97
RW
OOS
2: Yes
0: Travel feedback
sensor detected
1: Output Block
Scheduled
2: Trigger Capturing
98
RO
3: Output Block in
Normal Mode
4: Write Lock is on
5: Resource Block in
Auto Mode
99
RW
100
RO
Transducer Block
Protect
Initial Value
Category
C
SETUP
Data Type: Enum (Uint8)
kPa
SETUP
Data Type: Enum (Uint8)
Data Type: Enum (Uint8)
Travel units for spec sheet
mm
SETUP
ACTUAL_TRAVEL and
RATEDTRAVEL only.
Data Type: Enum (Uint8)
Not used for spec sheet
mm
SETUP
ACTUAL_TRAVEL OR
RATEDTRAVEL
2
cm
SETUP
Data Type: Enum (Uint8)
N/m
SETUP
Data Type: Enum (Uint8)
Data Type:Uint16
which transducer block channels
will be sent to each of the 8 MAI
1
SETUP
channels. No scaling or other
conversion will be done. Values will
be sent in the currently defined
2
SETUP
units. If set to 0, then no output to
MAI (status will be set to BAD).
3
SETUP
1=FINAL_VALUE
2=TRAVEL_TARGET
4
SETUP
3=FINAL_POSITION_VALUE
4=TRAVEL
5=SUPPLY_PRESS
5
SETUP
6=ACT_PRESS_A
7=ACT_PRESS_B
6
SETUP
8=ACT_PRESS_DIFF
9=DRIVE_SIGNAL
10=TRAVEL_DEVIATION
7
SETUP
11=TEMPERATURE
12=CYCLE_COUNT
8
SETUP
13=TRAVEL_ACCUM
Data Type: Enum (Uint8)
Controls which output block (AO or
1: AO Block
SETUP
DO) the transducer block will
respond to.
Data Type: Enum (Uint8)
Controls whether the status of the
PV fed back to the output block
1: No
SETUP
from the transducer block will be
affected by an active PlantWeb
alert.
Data Type: Bit String (2 bytes)
Data Type: Bit String (4 bytes)
Data Type: DS−65
Description
4
This defines
4-63

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Fisher FIELDVUE DVC6000f and is the answer not in the manual?

Questions and answers

Table of Contents