DVC6000f Digital Valve Controllers
Label
PARAMETER_NAME
SPEC_SHEET_ACT
Actuator Size
ACTUATOR SIZE
Effective Area
EFFECTIVE AREA
Air
AIR
Lower Bench Set
LOWER_BENCH_SET
Upper Bench Set
UPPER_BENCH_SET
Nominal Supply Pressure
NOMINAL_SUPPL Y_PRESSURE
4
Spring Rate
SPRING_RATE
Stroking Time Open
STROKING_TIME_OPEN
Stroking Time Close
STROKING_TIME_CLOSE
Lever Style
LEVER_STYLE
Lever Arm Length
MOMENT_ARM
DEVICE_RECORD
Temperature Maximum
TEMP_MAX
Temperature Maximum Time
TEMP_MAX_TIME
Temperature Minimum
TEMP_MIN
Temperature Minimum Time
TEMP_MIN_TIME
Supply Pressure Maximum
SUPP_PRESS_MAX
Supply Pressure Maximum Time
SUPP_PRESS_MAX_TIME
Supply Pressure Minimum
SUPP_PRESS_MIN
Supply Pressure Minimum Time
SUPP_PRESS_MIN_TIME
Comm Error Count
COMM_ERROR_COUNT
Protection
PROTECTION
PERF_DIAG
PD Run
PD_COMMAND
PD Status
PD_STATUS
PD Configuration
PD_CONFIG
PD Extra
PD_EXTRA
4-62
Table 4-13. Transducer Block Parameter Definitions (Continued)
Index
RO /
Mode
Range
Number
RW
85
85.1
RW
ALL
85.2
RW
ALL
1=open
85.3
RW
ALL
2=close
85.4
RW
ALL
85.5
RW
ALL
85.6
RW
ALL
85.7
RW
ALL
85.8
RW
ALL
85.9
RW
ALL
1=Pivot Point
85.10
RW
ALL
2=Rack & Pinion
85.11
RW
ALL
86
86.1
RO
N/A
86.2
RO
N/A
86.3
RO
N/A
86.4
RO
N/A
86.5
RO
N/A
86.6
RO
N/A
86.7
RO
N/A
86.8
RO
N/A
86.9
RW
N/A
1=None
2=Calibration
87
RW
ALL
3=Setup & Calibration
4=All
88
AUTO
1=PD On
88.1
RW
MAN
2=PD Off
1=Not Running
88.2
RO
ALL
2=Running
88.3
RW
ALL
0
88.4
RW
ALL
−Continued−
Protect
Initial Value
Category
NULL
ALL
Data Type: Visible String
0.00
ALL
Data Type: Float
0
ALL
Data Type: Enum (Uint8)
0.00
ALL
Data Type: Float
0.00
ALL
Data Type: Float
0.00
ALL
Data Type: Float
0.00
ALL
Data Type: Float
Data Type: Float
0.00
ALL
Seconds
Data Type: Float
0.00
ALL
Seconds
0
ALL
Data Type: Enum (Uint8)
0.00
ALL
Data Type: Float
These parameters can only reset
through VL/DD.
Data Type: Float
−9999.99
N/A
Highest temperature recorded
Zero time
N/A
Data Type: Time Value
Data Type: Float
9999.99
N/A
Lowest temperature recorded
Zero time
N/A
Data Type: Time Value
Data Type: Float
0.0
N/A
Highest supply pressure recorded
Zero time
N/A
Data Type: Time Value
Data Type: Float
9999.99
N/A
Lowest supply pressure recorded
Zero time
N/A
Data Type: Time Value
0
SETUP
Not used by the DVC6000f
Data Type: Enum
Write lock enable/disable. If setting
is at or above a parameters
2=Calibration
NONE
protection level then that parameter
is read-only.
Data Type: Enum
1=PD On
NONE
Controls whether PD will run or not.
Data Type: Enum
NONE
Status of performance diagnostics.
Data Type: Bit String
NONE
Bit string for configuring PD setup
and options.
Data Type: Uint32
0
NONE
Extra 32 bit integer for sending
values to PD.
Description
December 2009