DVC6000f Digital Valve Controllers
Label
PARAMETER_NAME
FINAL_POSITION_VALUE
Travel Status (Decharacterized)
STATUS
Travel (Decharacterized)
VALUE
Travel Proportional Gain
SERVO_GAIN
Travel Integral Gain
SERVO_RESET
Travel Velocity Gain
4
SERVO_RATE
Actuator Fail Action
ACT_FAIL_ACTION
Actuator Manufacturer
ACT_MAN_ID
Actuator Model Number
ACT_MODEL_NUM
Actuator Serial Number
ACT_SN
Valve Manufacturer
VALVE_MAN_ID
Valve Model Number
VALVE_MODEL_NUM
Valve Serial Number
VALVE_SN
Valve Style
VALVE_TYPE
Calibration Location
XD_CAL_LOC
Calibration Date
XD_CAL_DATE
Calibration Person
XD_CAL_WHO
SETPOINT_D
Setpoint(D) Status
STATUS
Setpoint(D)
VALUE
TRAVEL_D
Travel(D) Status
STATUS
Travel (D)
VALUE
4-44
Table 4-13. Transducer Block Parameter Definitions (Continued)
Index
RO /
Mode
Range
Number
RW
17
17.1
RO
N/A
−25 to 125%
17.2
RO
N/A
MAN
> = 0
18
RW
OOS
> = 0 , = 0 causes wind
MAN
19
RW
OOS
down
MAN
> = 0
20
RW
OOS
0=Uninitialized
MAN
21
RW
1=Self Closing
OOS
2=Self Opening
22
RW
ALL
23
RW
ALL
24
RW
ALL
25
RW
ALL
26
RW
ALL
27
RW
ALL
1=Sliding Stem
28
RW
ALL
2=Rotary
29
RW
ALL
30
RW
ALL
31
RW
ALL
32
MAN
32.1
RW
OOS
MAN
0 = closed 1 = open
32.2
RW
OOS
5,10,15.. = %
33
33.1
RO
N/A
0 = closed 1 = open
33.2
RO
N/A
5,10,15.. = %
−Continued−
Protect
Initial Value
Category
Data Type: DS-65
In Travel Control: Valve travel in %,
decharacterized to correlate with
Setpoint (FINAL_VALUE [13]).
N/A
N/A
In Pressure Control: Implied valve
travel as a % of pressure range,
decharacterized to correlate with
N/A
Setpoint (FINAL_VALUE [13]).
Controls AI channel 3.
Data Type: Float
4.4
SETUP
Travel Control Only. Gain of servo.
Data Type: Float
Travel Control Only. If set to 0, will
9.4
SETUP
cause integrator to wind down.
Data Type: Float
3.0
SETUP
Travel Control Only. Rate of servo.
Data Type: Enum (Uint8)
1=
SETUP
Action performed by actuator in the
Self Closing
event of air pressure.
Data Type: Uint32
0x5100
SETUP
The actuator manufacturer
identification number.
Data Type: Visible String
Null
SETUP
Model number of actuator.
Data Type: Visible String
Null
SETUP
Serial number of actuator.
Data Type: Uint32
0x5100
SETUP
The valve manufacturer
identification number.
Data Type: Visible String
Null
SETUP
The valve model number.
Data Type: Visible String
Null
SETUP
The valve serial number.
Data Type: Enum (Uint8)
1=Sliding Stem
SETUP
Selects Rotary or Sliding Stem.
Data Type: Visible String
Null
CAL
Where device was last calibrated.
Data Type: Date
Uninitialized
CAL
Date of last calibration.
Data Type: Visible String
Null
CAL
Name of person performing last
calibration.
Data Type: DS_66
SETPOINT_D is not updated
unless the DO block is selected in
FEATURE_SEL.
STATUS indicates the validity of
NONE
value, set by the DO block
OUT.STATUS
VALUE is the discrete value of
setpoint. Only values of 0, 1, or
NONE
increments of 5 up to 95 are
allowed. Written by DO channel 22.
Data Type: DS_66
STATUS indicates the validity of
VALUE.
N/A
VALUE: 0=closed , 1=open
5,10,15.. = %. Controls DI Channel
N/A
23
Description
December 2009