Emerson Fisher FIELDVUE DVC6000f Instruction Manual page 136

Digital valve controllers
Hide thumbs Also See for Fisher FIELDVUE DVC6000f:
Table of Contents

Advertisement

DVC6000f Digital Valve Controllers
Label
PARAMETER_NAME
Simulate
SIMULATE
SIMULATE_STATUS
SIMULATE_VALUE
TRANSDUCER_STATUS
TRANSDUCER_VALUE
ENABLE/DISABLE
Process Value Scale
PV_SCALE
4
Transducer Scale
XD_SCALE
Grant Deny
GRANT_DENY
GRANT
DENY
I/O Options
IO_OPTS
Status Options
STATUS_OPTS
Readback
READBACK
Cascade Input
CAS_IN
4-76
Table 4-24. Analog Output Function Block Parameter Definitions (Continued)
Index
RO /
Block
Number
RW
Mode
10
10.1
RW
ALL
10.2
RW
ALL
10.3
RO
ALL
10.4
RO
ALL
0: Not Initialized
10.5
RW
ALL
1: Simulation Disable
2: Simulation Active
EU at 100%
EU at 0%
11
RW
OOS
Units index
Decimal Point
EU at 100%
EU at 0%
12
RO
OOS
Units index
Decimal Point
13
0: Program
13.1
RW
ALL
1: Tune
2: Alarm
13.2
RW
ALL
3: Local
1: SP tracks PV in
Man
3: SP tracks PV in LO
or Iman
4: SP Track retained
target in Man or LO
5: Increase to Close
6: Fault State to value
14
OOS
7: Use Fault State
value on restart
8: Target to Man if
Fault State activated
9: Use PV for
BKCAL_OUT
4: Propagate Failure
15
OOS
Backward
Status
16
RO
N/A
Value
Status
17
ALL
Value
Initial
Range
Value
0
0
0
0
1: Simulation
Disabled
100
0
%
2
100 only
0 only
% only
2
All bits: 0
All bits: 0
0=freeze
1=go to Fault State
All bits: 0
value
0=SP
1=PV
All bits: 0
Dynamic
BAD:
NC:
const
0
−Continued−
Description
Data Type: DS-82
Allows the analog input to be manually supplied
when simulate is enabled. When simulation is
disabled, the simulate value and status track
actual value & status.
Data Type: DS-68
The high and low scale values, engineering units
code, and number of decimal places to be used in
displaying the PV parameter and parameters
which have the same scaling as PV.
Data Type: DS-68
The high and low scale values and engineering
units code are read only. This parameter
determines the number of digits to the right of the
decimal point used with the value obtained from
the transducer for a specified channel.
Data Type: DS-70
Options for controlling access of host computers
and local control panels to operating, tuning, and
alarm parameters of the block.
GRANT: 1 = granted, 0= N/A
DENY: 1 = denied, 0 = N/A
Data Type: Bit String (2 byte)
0=disable
1=enable
Allows you to select the type of tracking and the
output value when a fault condition occurs.
Data Type: Bit String
0=disable
1=enable
Options the user may select for the block
processing of status.
Data Type: DS-65
Readback is the de-characterized valve position
as reported by the transducer block parameter
FINAL_POSITION_VALUE [17]. This correlates
with the AO block parameter OUT [9], which is
the setpoint to the transducer. READBACK is the
simulated input if SIMULATE is enabled or the
transducer block feedback if SIMULATE is
disabled.
Data Type: DS-65
The setpoint value from another function block.
December 2009